Forum Post: [Web services gateway] Get document path
How to retrieve document path using Projectwise web services gateway?
View ArticleForum Post: RE: MicroStation Design Script
I have a question, can you add to the script to say I want a certain level to plot a certain pen width? if so how do I place that in the script.
View ArticleForum Post: RE: MicroStation Design Script
Hello Mark. Have a look in ProjectWise InterPlot Help under Plotting MicroStation Data - Using Design Scripts / Pen tables - IPLOT Comparison Keywords. A lot of examples can be found there for every...
View ArticleForum Post: RE: New ProjectWise InterPlot CONNECT Edition driver packs now...
[quote userid="2295" url="~/products/projectwise/content_publishing/f/content-publishing-forum/168834/new-projectwise-interplot-connect-edition-driver-packs-now-available"]For more information on the...
View ArticleForum Post: RE: Bentley Automation Service CONNECT Edition Update 3.1...
Does it work with Projectwise v8i?
View ArticleForum Post: RE: Bentley Automation Service V8i (SELECTseries 6) Available for...
No longer available for download
View ArticleForum Post: Design Scripts Cannot Set Line Thickness on Dimensions with...
We are having a problem with apparent changes to the logic of design scripts in IPlot CONNECT Edition. We are using IPlot Organizer CE 10.00.01.22. In our organization, we do not use project- or...
View ArticleForum Post: Design Script in CONNECT Edition Not Recognizing Tag Elements
Running IPlot Organizer 10.00.01.22 In V8i, our design script had a section that defined our endcap condition for linestyle 0 and system line style patterns: SWITCH (style) case 0? IF (CLASS ==...
View ArticleForum Post: RE: Design Scripts Cannot Set Line Thickness on Dimensions with...
I recommend replacing the weight-to-thickness switch block in your design script with a series of "pen_width_ " assignments. These are supported in InterPlot CE, but I don't believe are in the...
View ArticleForum Post: RE: Design Script in CONNECT Edition Not Recognizing Tag Elements
That's due to underlying changes in MicroStation CONNECT Edition that InterPlot has no control over. "Tag" (aka "Attribute" aka type 37) elements are no longer represented as header-like objects with...
View ArticleForum Post: RE: Design Scripts Cannot Set Line Thickness on Dimensions with...
PEN_WIDTH_ works like a charm! Was able to successfully convert the weight switch block to a pen width mapping block. Thank you soooooo much!
View ArticleForum Post: What causes the alert message "CLS, Use of ProjectWise InterPlot...
Colleague is getting this message when she opens DGN files: "CLS, Use of ProjectWise InterPlot Organizer has been disabled" Google returned 0 results. Any suggestions?
View ArticleWiki Page: How do I create a .pdf with searchable text using the PDF Standard...
Solution Installed ProjectWise InterPlot Organizer 10.00.01.22 and MicroStation CONNECT Edition 10.12.00.40 or higher Make sure to enable "Searchable Text" and select PDF/A-1b under "PDF Standard" in...
View ArticleForum Post: Creating Renditions from CAD2017 dwgs - not picking up ctb
I'm trying to create a renditions profile for an autocad based project, with a ctb. i have run through the .set file setup and gone through and added aplot along with all the required options. however...
View ArticleForum Post: RE: Creating Renditions from CAD2017 dwgs - not picking up ctb
"APLOT" is a truly obsolete component of InterPlot Organizer which is overdue for removal. It only supports very old versions of the DWG format (2000 and earlier IIRC). What you need is an "IPLOT"...
View ArticleWiki Page: Rendition does not update title block attribute if attribute or...
By default, iCS for PDF does not perform attribute exchange inside references, to avoid problems with concurrent extractors. Best practice is for title blocks to be in the master DGN. In case you still...
View ArticleForum Post: RE: Multiple Page PDF from Models without IPS files
Dawn, has this change request been implemented into iCS? we need the ability to create multi page PDF from multiple DGN files instead of one PDF per DGN, without having to use IPS files.
View ArticleForum Post: Add PDF's to existing Archives in DPR
We were early adopters of and have been using DPR for 20 years and have archives that predate the PDF output. I need/want to create the PDF from the existing archives without having to resubmit the...
View ArticleForum Post: IP_PW_SETTINGS_PATH vs. IP_SETTINGS_PATH behavior
When outside of ProjectWise It seems like the first directory in the variable IP_SETTINGS_PATH is used as the default location in the dialog when choosing a set file. When inside of Projectwise and...
View ArticleForum Post: RE: Multiple Page PDF from Models without IPS files
Let me add our bid (DelDOT) into this request as well. Even if it was something as simple as taking the PDFs created from the initial rendition process and having a special rendition process that will...
View Article