Forum Post: RE: Blank IPLOT Preview
We will check that.... Just curious though. If the IPLOT preview looks fine from within the Microstation environment, do you think it still might be the driver?
View ArticleForum Post: RE: Blank IPLOT Preview
The IPLOT dialog and Organizer use VPR for print previewing, so the video driver is probably okay. If an Organizer preview is blank, make sure the plot area or model contains graphics. For a test, save...
View ArticleWiki Page: All documents in an iCS Job are getting processed even though the...
Applies To Product(s): Bentley i-model Composition Server for PDF Version(s): Environment: Windows Server 2008 R2 Area: PDF Subarea: Original Author: Todd Combs, Bentley Technical Support Group Problem...
View ArticleForum Post: Untitled Viewport Created By Interplot
When I create a pdf from Interplot it creates two "Untitled" viewports. These viewports have nothing to do with the scale of the drawing, and thus should not be there. Where is the setting in Interplot...
View ArticleForum Post: RE: Untitled Viewport Created By Interplot
Matthew, Perform a test with "Disable Saved Views" enabled in the PDF Format Configuration dialog.
View ArticleForum Post: RE: Untitled Viewport Created By Interplot
Thanks for the quick reply. I tried that and still have the same result. I gleaned a little more information, the scales on the viewports are 1":8.73504" and 1":11.6467". One other thing... I don't...
View ArticleForum Post: RE: Untitled Viewport Created By Interplot
A multiple page PDF can be created if the settings file has “Create one plot from each matching shape” enabled, and the file contains multiple shapes that match your plot shape. Is each viewport in the...
View ArticleForum Post: RE: Untitled Viewport Created By Interplot
Todd, Thanks for following up on this. Using our full scale printer settings file to generate pdfs required us to manually crop a 48x36 pdf to create a correctly sized 22x34 pdf... ( See BorderShape...
View ArticleForum Post: RE: Untitled Viewport Created By Interplot
Thank you Todd! He has solved the problem! The short term solution is to add: IPLOTSRV_NO_PDF_MEASURE = true to the iplotsrv.cfg file. The long term solution may be up for debate... We don't use the...
View ArticleForum Post: RE: File Transfer ActiveX Control not loading in IE 11...
Dear David, thanks for sharing your experience. Actually, we have the same issue and File Transfer Control does not load. We tried both of your hints but non of them solved the issue. Do you use *.590...
View ArticleForum Post: RE: File Transfer ActiveX Control not loading in IE 11...
I've updated the post to reflect the latest information that I have. You may have to uninstall the Active X components so that the latest ones are downloaded and installed from the server. If that is...
View ArticleForum Post: RE: File Transfer ActiveX Control not loading in IE 11...
Thanks David, it is working now.
View ArticleComment on ProjectWise InterPlot Organizer
Can users use the virtual queue on an ICS server that is running Ics for PDF as the default queue in Iplot for ad hoc jobs within Microstation? We have 22 Iplot servers around the country and we are...
View ArticleForum Post: Client accessing folders through the Web Portal cannot create...
None of our Clients can create folders inside folders they have permissions to perform this task. The Pop-up menu opens and says loading but never goes any further. I have tried checking permissions...
View ArticleForum Post: Projectwise Interplot Organizer Compatibility with Windows 8
This is the error I get when trying to create multiple cross section plots from a single file. About 200 sheets or so. If I use an old computer that has Windows 7 on it still, the plots create without...
View ArticleForum Post: RE: Projectwise Interplot Organizer Compatibility with Windows 8
The current release of ProjectWise InterPlot Organizer has not been certified against Windows 8. Our next version will be certified against it as well as Windows 10. If you send me a private message we...
View ArticleForum Post: RE: Projectwise Interplot Organizer Compatibility with Windows 8
So when is the expected release of this new version?
View ArticleForum Post: RE: Projectwise Interplot Organizer Compatibility with Windows 8
I don't have a specific date but the plan is to release it some time after MicroStation CONNECT edition is released. In the mean time you may try adding the following variables to the iplot.cfg...
View ArticleWiki Page: Understanding the iCS for PDF “Output Destination Folder”...
Understanding the iCS for PDF “Output Destination Folder” rendition component Create Version/Overwrite options When creating Rendition Profiles for use with Bentley i-model Composition Server for PDF ,...
View ArticleForum Post: RE: Projectwise Interplot Organizer Compatibility with Windows 8
This answer worked. I only had to change one other variable not listed here. In the iplot.cfg file I had to change this variable: IPLOT_SHAPE_LIMIT = 50 I changed it to 500. This controls the maximum...