Wiki Page: Is there an InterPlot Design Script Assignment Keyword that corresponds the MicroStation Pen Table (or Autocad CTB) “Screening” setting?

$
0
0
      Applies To        Product(s): ProjectWise InterPlot Organizer   Version(s): System.Data.DataRowView   Environment:  N\A   Area:  General   Subarea:  N\A   Original Author: Frank Reimann, Bentley Technical Support Group       Problem: MicroStation Pen Table (or Autocad CTB) can have Screening factors. Is there an InterPlot Design Script Assignment Keyword that corresponds the MicroStation Pen Table (or Autocad CTB)  “Screening” setting? Solution: W e do not have an exactly the same InterPlot Design Script Assignment Keyword. The InterPlot Assignment Keyword Transparency is equivalent to the Screening keyword in MicroStation Pen Table (or Autocad CTB) , but the values are reversed, so Screening = 20 in the MicroStation Pen Table would be Transparency=80 in the design script.