Applies To Product(s): PROJECTWISE DYNAMIC PLOT SERVICE Version(s): N\A Environment: N\A Area: IPLOT Subarea: N\A Original Author: Edwin Yepes, Bentley Technical Support Group Problem I have a new install of ProjectWise Dynamic plot on a new Windows Server 2008 and I get the following error in the InterPlot Errorlog when I plot with Dynamic Plot enabled: == 5.KCHL416 (Untitled.ips) on Xerox WorkCentre 7335 PS from jcriley@KCHL416 (Tue Oct 18 14:02:33 CDT 2011) == +++++++++++Exception Message:++++++++++Object reference not set to an instance of an object. +++++++++++Exception Source:++++++++++Bentley.DPS.DPSDriverProxy +++++++++++Stack Trace:++++++++++ at Bentley.DPS.DPSDriverProxy.DPSDriverWrapper.GetPlotServerID(String plotServerName, String queueName)Failure. Exception with Web Service: Web Service may be unavailable. Correct problem with Web Service! ODI-F-INTERNAL an internal error occurred COMPMFI-E-COMPMFI, Error in plotting document See Also: 66085 Solution Run the “PW Dynamic Plot Service Configure� utility on the ProjectWise Dynamic Plot Service machine so that it can connect to the pattern service. See Also
↧